5th International Conference on Biomedical Engineering in by Vo Van Toi, Tran Ha Lien Phuong

By Vo Van Toi, Tran Ha Lien Phuong

This quantity provides the court cases of the 5th foreign convention at the improvement of Biomedical Engineering in Vietnam which was once held from June 16-18, 2014 in Ho Chi Minh urban. the amount displays the growth of Biomedical Engineering and discusses difficulties and ideas. I goals picking out new demanding situations, and shaping destiny instructions for examine in biomedical engineering fields together with clinical instrumentation, bioinformatics, biomechanics, scientific imaging, drug supply remedy, regenerative medication and entrepreneurship in clinical devices.

Show description

Read or Download 5th International Conference on Biomedical Engineering in Vietnam PDF

Best international_1 books

Real-World Wireless Sensor Networks: Proceedings of the 5th International Workshop, REALWSN 2013, Como (Italy), September 19-20, 2013

This edited booklet offers the result of the fifth Workshop on Real-world instant Sensor Networks (REALWSN). the aim of this workshop used to be to assemble researchers and practitioners operating within the zone of sensor networks, with specialize in real-world experiments or deployments of instant sensor networks.

Evolutionary Multi-Criterion Optimization: 5th International Conference, EMO 2009, Nantes, France, April 7-10, 2009. Proceedings

This ebook constitutes the refereed complaints of the fifth overseas convention on Evolutionary Multi-Criterion Optimization, EMO 2009, held in Nantes, France in April 2009. The 39 revised complete papers provided including five invited talks have been conscientiously reviewed and chosen from seventy two submissions.

The international encyclopedia of ethics / Volume 3, D-Fal

Unequalled in scholarship and scope, The overseas Encyclopedia of Ethics is the definitive single-source reference paintings on Ethics, on hand either in print and on-line. contains over seven-hundred entries, starting from one thousand to 10,000 phrases in size, written by means of a world forged of topic expertsIs prepared across 9 totally cross-referenced volumes including a finished indexProvides transparent definitions and factors of all parts of ethics together with the themes, routine, arguments, and key figures in Normative Ethics, Metaethics, and sensible EthicsCovers the main philosophical and non secular traditionsOffers an unparalleled point of authority, accuracy and stability with all entries being blind peer-reviewed

Model-Based Safety and Assessment: 4th International Symposium, IMBSA 2014, Munich, Germany, October 27-29, 2014. Proceedings

This e-book constitutes the refereed complaints of the 4th foreign Symposium on Model-Based safeguard and evaluate, IMBSA 2014, held in Munich, Germany, in October 2014. The 15 revised complete papers offered have been rigorously reviewed and chosen from a variety of submissions. The papers are equipped in topical sections on modeling paradigms, validation and checking out, fault detection and dealing with, defense evaluation within the automobile area, and case reports.

Extra info for 5th International Conference on Biomedical Engineering in Vietnam

Example text

Keywords— ultrasound, osteoporosis, BMD, DXA, radius. I. INTRODUCTION The objective of this study is to enhance the ability of ultrasound to non-invasively assess bone. As is well known, osteoporotic fractures are a major public health problem associated with high degrees of morbidity and mortality [1, 2]. 9 million fractures annually, resulting in an osteoporotic fracture every 3 seconds [3]. Osteoporosis is estimated to affect 200 million women worldwide - approximately one-tenth of women aged 60, one-fifth of women aged 70, two-fifths of women aged 80 and two-thirds of women aged 90 [3].

5 (only IFI44L target present). The result indicates that when a target ssDNA was present only the SERS peaks associated with the complementary MS probes were significantly quenched (indicated by arrows). For example, in the Fig. 4, only the SERS peaks 1 to 4 associated with the IFI27 MS nanoprobes were quenched when the IFI27 target was present, indicating that only the IFI27 MS nanoprobes were in open state. In contrast, the SERS peaks 1* and 2* associated with the second MS nanoprobes (IFI44L MS) remained high, indicating that the second nanoprobes were still in closed state due to the absence of its target ssDNA.

The device rests on a desktop and is portable, and permits real-time evaluation of the radial BMD. The device measures the time delays associated with three distinct propagation pathways through the forearm, and from these time delays an ultrasound-based estimate, BMDUS, of the BMD is computed. A clinical IRBapproved study measured ultrasonically seventy-eight adults at the 1/3 radius. BMD was also measured (“BMDDXA”) at the same anatomical site and time using DXA. 001). In conclusion, although x-ray methods are effective in bone mass assessment, osteoporosis remains one of the largest under-diagnosed diseases in the world today.

Download PDF sample

Rated 4.66 of 5 – based on 19 votes